| Specification |
Size Range |
| Glass-fibre Wound, Polyester or
Polyesterimide Varnish treated
Bare or Enamelled Rectangular
Copper Wire, Temp. index 180 |
IS 13730 /
IEC 60317
Part-31 : 1997 |
Cross Sectional area
3 to 75 Sqmm
Width 3 to 20 mm
Thick 1.0 to 6.0 mm |
| Glass-fibre Wound, Polyester or
Polyesterimide Varnish treated
Bare or Enamelled Rectangular
Copper Wire, Temp. index 155 |
IS 13730 /
IEC 60317
Part-32 : 1997 |
Cross Sectional area
3 to 75 Sqmm
Width 3 to 20 mm
Thick 1.0 to 6.0 mm |
| Glass-fibre Wound, Silicone
Varnish treated
Bare or Enamelled Rectangular
Copper Wire, Temp. index 200 |
IS 13730 /
IEC 60317
Part-33 : 1997 |
Cross Sectional area
3 to 55 Sqmm
Width 3 to 11 mm
Thick 1.0 to 5 mm |
| Specification for Varnish
Bonded Glass-Fibre Braided
Rectangular Copper Conductor |
IS 6181
: 1971 |
Cross Sectional area
4.5 to 15 sqmm
Width 3 to 6 mm
Thick 1.5 to 2.5 mm |
| Varnish bonded glass fibre covered
Round bare copper conductor |
IS 4685 Part 1
: 1968 |
Conductor Size
2 mm to 6 mm |
| Enamelled and Varnish
bonded glass fibre covered round
copper conductor |
IS 11184
: 1984 |
Conductor Size
2 mm to 5 mm |